{"id":1898,"date":"2025-08-12T11:26:32","date_gmt":"2025-08-12T09:26:32","guid":{"rendered":"https:\/\/www.scanxpert.eu\/?page_id=1898"},"modified":"2026-02-16T13:40:37","modified_gmt":"2026-02-16T12:40:37","slug":"optisches-setup-scanxpert-fx","status":"publish","type":"page","link":"https:\/\/www.scanxpert.eu\/en\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/","title":{"rendered":"Optical Setup ScanXpert FX"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Adjusting the field of view for the ScanXpert FX is divided into two parts.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>During the optical setup, you adjust the mechanical and optical parameters of your scanner hardware.<\/li>\n\n\n\n<li>The calibration process calculates the environmental parameters of the setup.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">optical setup:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">As an example, we will set the scanner to a field of view of 250 x 200 mm.<br>This selected field of view is a good average for different scanning projects.<br>If you prefer a different field of view, change the parameters according to<br><strong>Table 1<\/strong> below.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"568\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg\" alt=\"Scanxpert FX Sichtfeld 250 x 200 mm.\" class=\"wp-image-1904\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm-300x170.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm-768x436.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig. field of view 250 x 200 mm.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"590\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Startposition-optisches-Setup.jpg\" alt=\"Abb. Startposition optisches Setup\" class=\"wp-image-1909\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Startposition-optisches-Setup.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Startposition-optisches-Setup-300x177.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Startposition-optisches-Setup-768x453.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Startposition-optisches-Setup-18x12.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig. starting position optical setup <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Position the scan head at approximately the same height as the center of the calibration master.<\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"566\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster.jpg\" alt=\"Abb: Abstand zwischen Scankopf und Kalibriermaster\" class=\"wp-image-1908\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster-300x170.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster-768x435.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig.: Distance between scan head and calibration master<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Position the scan head 490 mm away from the calibration master.<\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">If you are using a different viewing area than 250 x 200 mm, use the spacing specified in Table 1 (matching the viewing area you are using).<\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"464\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster_2.jpg\" alt=\"Abb: Abstand zwischen Scankopf und Kalibriermaster\" class=\"wp-image-1914\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster_2.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster_2-300x278.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Abstand-zwischen-Scankopf-und-Kalibriermaster_2-13x12.jpg 13w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig.: Distance between scan head and calibration master<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">With a field of view of 250 x 200 mm, place the calibration plate at a distance of 490 mm in front of the lenses of the scan head.<\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">For a different field of view, select the correct distance using Table 1.<\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><br>field of view<\/td><td class=\"has-text-align-center\" data-align=\"center\">distance<\/td><td class=\"has-text-align-center\" data-align=\"center\">Master<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">80 x 60 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">140 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">100 x 100 step 5,0 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">100 x 80 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">100 x 100 step 5,0 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">150 x 120 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">290 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 7,5 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">200 x 160 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">390 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">250 x 200 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">490 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">300 x 240 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">580 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">350 x 280 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">680 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">400 x 320 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">780 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">450 x 360 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">880 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">500 x 400 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">1040 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 150 step 15 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Table 1: Working distance depending on the field of view (calibration pattern to be used from the calibration master template).<\/p>\n\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\">Start the ScanXpert Suite software.<\/h3>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph translation-block\">On the ScanXpert Suite welcome screen, select the menu item \u201c<strong>Options and Scanner Settings<\/strong>\u201d<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"366\" height=\"252\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-optionen-einstellungen.jpg\" alt=\"Abb: Optionen und Scanner Einstellungen\" class=\"wp-image-1918\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-optionen-einstellungen.jpg 366w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-optionen-einstellungen-300x207.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-optionen-einstellungen-18x12.jpg 18w\" sizes=\"auto, (max-width: 366px) 100vw, 366px\" \/><figcaption class=\"wp-element-caption\">Fig.: Options and scanner settings<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">In the following menu, select the \"Scanner Settings\" button to start the optical setup wizard.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"127\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-scanner-einstellungen.jpg\" alt=\"\" class=\"wp-image-1920\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-scanner-einstellungen.jpg 600w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-scanner-einstellungen-300x64.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-scanner-einstellungen-18x4.jpg 18w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Once the Optical Setup Assistant is started, the scan head projector generates a vertical line.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"432\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-vertikale-linie-optisches-setup.jpg\" alt=\"\" class=\"wp-image-1922\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-vertikale-linie-optisches-setup.jpg 600w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-vertikale-linie-optisches-setup-300x216.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-vertikale-linie-optisches-setup-18x12.jpg 18w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Position the calibration target in front of the scanner so that the projected line passes through the center point of the bold markings. Please ensure that the distance between the calibration target and the scanner remains 490 mm (with a field of view of 250 x 200 mm).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"474\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Projektor.jpg\" alt=\"Abb: Ansicht Projektor.\" class=\"wp-image-1925\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Projektor.jpg 600w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Projektor-300x237.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Projektor-15x12.jpg 15w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption class=\"wp-element-caption\">Fig.: Projector view.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">There is a focus control on the top of the projector. Please adjust this until the projected line appears sharply defined on the calibration master.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">The cameras are activated during the optical setup!<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Pay attention to the screen content of the ScanXpert Suite.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"535\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/Ansicht-optisches-Setup-ScanXpert-Suite.jpg\" alt=\"Abb: Ansicht optisches Setup \u2013 ScanXpert Suite\" class=\"wp-image-1926\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/Ansicht-optisches-Setup-ScanXpert-Suite.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/Ansicht-optisches-Setup-ScanXpert-Suite-300x161.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/Ansicht-optisches-Setup-ScanXpert-Suite-768x411.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/Ansicht-optisches-Setup-ScanXpert-Suite-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig.: View of optical setup \u2013 ScanXpert Suite<\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"454\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen.jpg\" alt=\"Schrauben l\u00f6sen\" class=\"wp-image-1929\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen-300x272.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen-13x12.jpg 13w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig. loosen screws<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Loosen the two screws that secure the left camera to the guide rail.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">On the back of the guide rail is a scale that represents the selected field of view.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Move the camera to position 250 (or to the value for your desired field of view).<\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Pan the left camera towards the center of the calibration master shown on the left side of the computer screen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The yellow line of the crosshair generated by the camera (consisting of blue, green and a yellow line) must be shown directly on the black line.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">See the following illustration:<\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"721\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Ansicht-linke-Kamera-ScanXpert-Suite-Optisches-Setup.jpg\" alt=\"Abb 10: Ansicht linke Kamera ScanXpert Suite \u2013 Optisches Setup\" class=\"wp-image-1932\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Ansicht-linke-Kamera-ScanXpert-Suite-Optisches-Setup.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Ansicht-linke-Kamera-ScanXpert-Suite-Optisches-Setup-300x216.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Ansicht-linke-Kamera-ScanXpert-Suite-Optisches-Setup-768x554.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Ansicht-linke-Kamera-ScanXpert-Suite-Optisches-Setup-18x12.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig. 10: View of left camera ScanXpert Suite \u2013 Optical setup<\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"545\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen_2.jpg\" alt=\"\" class=\"wp-image-1935\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen_2.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen_2-275x300.jpg 275w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Schrauben-an-kamera-loesen_2-11x12.jpg 11w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig. loosen screws<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Repeat the process for the right camera:<\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">To do this, first loosen the two screws that fix the right camera to the guide rail.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pan the right camera towards the center of the calibration master shown on the right.<\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"825\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-rechte-Kamera-ScanXpert-Suite-Optisches-Setup.jpg\" alt=\"Abb 11: Ansicht rechte Kamera ScanXpert Suite \u2013 Optisches Setup\" class=\"wp-image-1936\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-rechte-Kamera-ScanXpert-Suite-Optisches-Setup.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-rechte-Kamera-ScanXpert-Suite-Optisches-Setup-300x248.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-rechte-Kamera-ScanXpert-Suite-Optisches-Setup-768x634.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-rechte-Kamera-ScanXpert-Suite-Optisches-Setup-15x12.jpg 15w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig. 11: View of right camera ScanXpert Suite \u2013 Optical setup<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>The yellow line of the crosshairs must be drawn directly on the black line.<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"545\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fixieren-rechte-Kamera.jpg\" alt=\"Abb: Fixieren Sie die rechte Kamera.\" class=\"wp-image-1937\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fixieren-rechte-Kamera.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fixieren-rechte-Kamera-275x300.jpg 275w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fixieren-rechte-Kamera-11x12.jpg 11w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig.: fix the right camera.<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Secure the position of the right camera by tightening the screws.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensure that the crosshairs remain directly on the black line of the grid shown on the right. (see Fig. 11)<\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"535\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Fadenkreuz-auf-der-schwarzen-Linie.jpg\" alt=\"\" class=\"wp-image-1938\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Fadenkreuz-auf-der-schwarzen-Linie.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Fadenkreuz-auf-der-schwarzen-Linie-300x161.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Fadenkreuz-auf-der-schwarzen-Linie-768x411.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Fadenkreuz-auf-der-schwarzen-Linie-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\">Adjusting the lenses<\/h3>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Carefully loosen the knurled screws of the lens on the left camera.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"545\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung.jpg\" alt=\"Abb: R\u00e4ndelschraube zur Fixierung der Fokuseinstellung\" class=\"wp-image-1941\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung-275x300.jpg 275w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung-11x12.jpg 11w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig.: Knurled screw for fixing the focus setting<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"545\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Blende.jpg\" alt=\"Abb: R\u00e4ndelschraube zur Fixierung der Blende\" class=\"wp-image-1942\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Blende.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Blende-275x300.jpg 275w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Blende-11x12.jpg 11w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig.: Knurled screw for fixing the aperture<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Open the lens aperture fully by turning the aperture ring completely to the left. The camera view displayed on the screen will become brighter or may even shift into the red range.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Repeat this process for the right camera.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"535\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Darstellung-ScanXpert-Suite-Optisches-Setup-bei-vollstaendig-geoeffneter-Blende.jpg\" alt=\"Abb: Darstellung ScanXpert Suite: Optisches Setup bei vollst\u00e4ndig ge\u00f6ffneter Blende\" class=\"wp-image-1946\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Darstellung-ScanXpert-Suite-Optisches-Setup-bei-vollstaendig-geoeffneter-Blende.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Darstellung-ScanXpert-Suite-Optisches-Setup-bei-vollstaendig-geoeffneter-Blende-300x161.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Darstellung-ScanXpert-Suite-Optisches-Setup-bei-vollstaendig-geoeffneter-Blende-768x411.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Darstellung-ScanXpert-Suite-Optisches-Setup-bei-vollstaendig-geoeffneter-Blende-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig.: ScanXpert Suite illustration: Optical setup with the aperture fully open<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Enable the option: Show focus:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"537\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Fokus-anzeigen.jpg\" alt=\"Abb: Ansicht Fokus anzeigen\" class=\"wp-image-1948\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Fokus-anzeigen.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Fokus-anzeigen-300x161.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Fokus-anzeigen-768x412.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Ansicht-Fokus-anzeigen-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig.: View to show focus<\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"545\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fokus-einstellen.jpg\" alt=\"Abb: Fokus einstellen.\" class=\"wp-image-1950\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fokus-einstellen.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fokus-einstellen-275x300.jpg 275w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Fokus-einstellen-11x12.jpg 11w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig.: Adjusting focus.<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Secure the position of the right camera by tightening the screws.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rotate the front lens ring for focus adjustment until the image from the left camera is sharply displayed on the screen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">repeat the process for the right camera.<\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"537\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Optisches-Setup-optimal-eingestellter-Fokus.jpg\" alt=\"Optisches Setup optimal eingestellter Fokus\" class=\"wp-image-1951\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Optisches-Setup-optimal-eingestellter-Fokus.jpg 1000w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Optisches-Setup-optimal-eingestellter-Fokus-300x161.jpg 300w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Optisches-Setup-optimal-eingestellter-Fokus-768x412.jpg 768w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/fx-Optisches-Setup-optimal-eingestellter-Fokus-18x10.jpg 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">Fig.: Optical setup: optimally adjusted focus<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Each marker displays a value for the detected focus setting.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">In the upper left corner of each camera view, an average value for the set focus is calculated. Adjust the focus setting by turning the focus ring on the lens until you reach the maximum possible value.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">The average value should be between 0.55 and 0.75.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">The higher the value, the better the scanner's image sharpness, and therefore the better the scan results!<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"545\" src=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung.jpg\" alt=\"Abb: R\u00e4ndelschraube zur Fixierung der Fokuseinstellung\" class=\"wp-image-1941\" srcset=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung.jpg 500w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung-275x300.jpg 275w, https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Raendelschraube-zur-Fixierung-der-Fokuseinstellung-11x12.jpg 11w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Fig.: Knurled screw for fixing the focus setting<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">Lock the focus ring on both cameras.<br><\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color wp-block-paragraph\">It is best to hold the focus ring firmly with your hand to prevent your optimal settings from changing.<\/p>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><br><br><div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div><\/p>","protected":false},"excerpt":{"rendered":"<p>Das Anpassen des Sichtfeldes f\u00fcr den ScanXpert FX untergliedert sich in zwei Teile. Optisches Setup: Beispielhaft stellen wir den Scanner auf ein Sichtfeld von 250 x 200 mm ein.Das gew\u00e4hlte Sichtfeld ist ein guter Mittelwert f\u00fcr unterschiedliche Scanprojekte.Falls Sie ein anderes Sichtfeld bevorzugen, ver\u00e4ndern Sie die Parameter anhand der weiter unten aufgef\u00fchrtenTabelle 1. Positionieren Sie&hellip;&nbsp;<a href=\"https:\/\/www.scanxpert.eu\/en\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">Optical Setup ScanXpert FX<\/span><\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":1891,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"class_list":["post-1898","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Optisches Setup ScanXpert FX - ScanXpert 3D Scanner<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.scanxpert.eu\/en\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Optisches Setup ScanXpert FX - ScanXpert 3D Scanner\" \/>\n<meta property=\"og:description\" content=\"Das Anpassen des Sichtfeldes f\u00fcr den ScanXpert FX untergliedert sich in zwei Teile. Optisches Setup: Beispielhaft stellen wir den Scanner auf ein Sichtfeld von 250 x 200 mm ein.Das gew\u00e4hlte Sichtfeld ist ein guter Mittelwert f\u00fcr unterschiedliche Scanprojekte.Falls Sie ein anderes Sichtfeld bevorzugen, ver\u00e4ndern Sie die Parameter anhand der weiter unten aufgef\u00fchrtenTabelle 1. Positionieren Sie&hellip;&nbsp;Read More &raquo;Optisches Setup ScanXpert FX\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.scanxpert.eu\/en\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/\" \/>\n<meta property=\"og:site_name\" content=\"ScanXpert 3D Scanner\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-16T12:40:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"568\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/\",\"url\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/\",\"name\":\"Optisches Setup ScanXpert FX - ScanXpert 3D Scanner\",\"isPartOf\":{\"@id\":\"https:\/\/www.scanxpert.eu\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg\",\"datePublished\":\"2025-08-12T09:26:32+00:00\",\"dateModified\":\"2026-02-16T12:40:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#primaryimage\",\"url\":\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg\",\"contentUrl\":\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.scanxpert.eu\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Hilfe\",\"item\":\"https:\/\/www.scanxpert.eu\/hilfe\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ScanXpert FX\",\"item\":\"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Optisches Setup ScanXpert FX\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.scanxpert.eu\/#website\",\"url\":\"https:\/\/www.scanxpert.eu\/\",\"name\":\"ScanXpert 3D Scanner\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.scanxpert.eu\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.scanxpert.eu\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.scanxpert.eu\/#organization\",\"name\":\"ScanXpert 3D Scanner\",\"url\":\"https:\/\/www.scanxpert.eu\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.scanxpert.eu\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/01\/favicon-128x128-1.png\",\"contentUrl\":\"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/01\/favicon-128x128-1.png\",\"width\":128,\"height\":128,\"caption\":\"ScanXpert 3D Scanner\"},\"image\":{\"@id\":\"https:\/\/www.scanxpert.eu\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Optisches Setup ScanXpert FX - ScanXpert 3D Scanner","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.scanxpert.eu\/en\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/","og_locale":"en_GB","og_type":"article","og_title":"Optisches Setup ScanXpert FX - ScanXpert 3D Scanner","og_description":"Das Anpassen des Sichtfeldes f\u00fcr den ScanXpert FX untergliedert sich in zwei Teile. Optisches Setup: Beispielhaft stellen wir den Scanner auf ein Sichtfeld von 250 x 200 mm ein.Das gew\u00e4hlte Sichtfeld ist ein guter Mittelwert f\u00fcr unterschiedliche Scanprojekte.Falls Sie ein anderes Sichtfeld bevorzugen, ver\u00e4ndern Sie die Parameter anhand der weiter unten aufgef\u00fchrtenTabelle 1. Positionieren Sie&hellip;&nbsp;Read More &raquo;Optisches Setup ScanXpert FX","og_url":"https:\/\/www.scanxpert.eu\/en\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/","og_site_name":"ScanXpert 3D Scanner","article_modified_time":"2026-02-16T12:40:37+00:00","og_image":[{"width":1000,"height":568,"url":"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/","url":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/","name":"Optisches Setup ScanXpert FX - ScanXpert 3D Scanner","isPartOf":{"@id":"https:\/\/www.scanxpert.eu\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#primaryimage"},"image":{"@id":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#primaryimage"},"thumbnailUrl":"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg","datePublished":"2025-08-12T09:26:32+00:00","dateModified":"2026-02-16T12:40:37+00:00","breadcrumb":{"@id":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#primaryimage","url":"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg","contentUrl":"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/04\/FX-Sichtfeld-250x200mm.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/optisches-setup-scanxpert-fx\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.scanxpert.eu\/"},{"@type":"ListItem","position":2,"name":"Hilfe","item":"https:\/\/www.scanxpert.eu\/hilfe\/"},{"@type":"ListItem","position":3,"name":"ScanXpert FX","item":"https:\/\/www.scanxpert.eu\/hilfe\/scanxpert-fx\/"},{"@type":"ListItem","position":4,"name":"Optisches Setup ScanXpert FX"}]},{"@type":"WebSite","@id":"https:\/\/www.scanxpert.eu\/#website","url":"https:\/\/www.scanxpert.eu\/","name":"ScanXpert 3D Scanner","description":"","publisher":{"@id":"https:\/\/www.scanxpert.eu\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.scanxpert.eu\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.scanxpert.eu\/#organization","name":"ScanXpert 3D Scanner","url":"https:\/\/www.scanxpert.eu\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.scanxpert.eu\/#\/schema\/logo\/image\/","url":"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/01\/favicon-128x128-1.png","contentUrl":"https:\/\/www.scanxpert.eu\/wp-content\/uploads\/2025\/01\/favicon-128x128-1.png","width":128,"height":128,"caption":"ScanXpert 3D Scanner"},"image":{"@id":"https:\/\/www.scanxpert.eu\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/pages\/1898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/comments?post=1898"}],"version-history":[{"count":41,"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/pages\/1898\/revisions"}],"predecessor-version":[{"id":1995,"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/pages\/1898\/revisions\/1995"}],"up":[{"embeddable":true,"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/pages\/1891"}],"wp:attachment":[{"href":"https:\/\/www.scanxpert.eu\/en\/wp-json\/wp\/v2\/media?parent=1898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}